How do you decide between using a self-expanding supraannular valve and a balloon-expandable valve for TAVR in patients with severe aortic stenosis and a small aortic annulus?
A supra-annular design intuitively allows for lower gradients on echo, so this endpoint was expected. But overall, the data thus far does indeed make a SEP an attractive choice as compared to a BEP, in patients with a small annulus. This is a fairly large subset of patients with AS. The risk of need...
Comments
at The George Washington University Hospital Future coronary access is a significant issue. But...
at LSU Health Sci Ctr-New Orleans I'm Sapien First in general. Best data overall in ...
at Bassett Medical Center I would agree with you both. Despite being a &lsqu...
Future coronary access is a significant issue. But...
I'm Sapien First in general. Best data overall in ...
I would agree with you both. Despite being a &lsqu...