Aside from limit due to extent of her hysterectomy, the patient's disease does not otherwise satisfy Peters' criteria
New comment by Radiation Oncologist at Vanderbilt-Ingram Cancer Center ( November 2, 2023)
I would generally boost cuff with HDR alone. 6 Gy x 3 if 45 Gy EBRT as per RTOG 0921 or 6 Gy x 2 if 50.4 Gy EBRT as per RTOG 0418. Both HDR prescriptions to vaginal mucosal su...