The Journal of urology 2023 Apr 26
Diagnostic Performance and Safety of F-rhPSMA-7.3 Positron Emission Tomography in Men With Suspected Prostate Cancer Recurrence: Results From a Phase 3, Prospective, Multicenter Study (SPOTLIGHT).   
ABSTRACT
PURPOSE
SPOTLIGHT (NCT04186845) evaluated diagnostic performance and safety of radiohybrid F-rhPSMA-7.3, a novel high-affinity positron emission tomography radiopharmaceutical.
MATERIALS AND METHODS
Men with prostate cancer recurrence underwent positron emission tomography/CT 50-70 minutes after intravenous administration of 296±20% MBq F-rhPSMA-7.3. To assess the coprimary end points (verified detection rate and combined region-level positive predictive value), 3 blinded, independent central readers evaluated the scans. Verified detection rate is equivalent to the overall detection rate × positive predictive value. Standard of truth was established for each patient using histopathology or confirmatory imaging. Statistical thresholds (lower bounds of the confidence intervals) of 36.5% and 62.5% were prespecified for verified detection rate and combined region-level positive predictive value, respectively Additional end points included detection rate, verified detection rate, and combined region-level positive predictive value in patients with histopathology standard of truth, and safety.
RESULTS
The overall F-rhPSMA-7.3 detection rate among all 389 patients with an evaluable scan was 83% (majority read). Among the 366 patients (median prostate-specific antigen 1.27 ng/mL) for whom a standard of truth (histopathology [n=69]/confirmatory imaging only [n=297]) was available, verified detection rate ranged from 51% (95% CI 46.1-56.6) to 54% (95% CI 48.8-59.3), exceeding the prespecified statistical threshold. Combined region-level positive predictive value ranged from 46% (95% CI 42.0-50.3) to 60% (95% CI 55.1-65.5) across the readers, not meeting the threshold. In the subset of patients with histopathology standard of truth, the verified detection rate and combined region-level positive predictive value were both above the prespecified thresholds (majority read, 81% [95% CI 69.9-89.6] and 72% [95% CI 62.5-80.7], respectively). No significant safety concerns were identified.
CONCLUSIONS
F-rhPSMA-7.3 offers a clinically meaningful verified detection rate for localization of recurrent prostate cancer. Despite missing the coprimary end point of combined region-level positive predictive value, the totality of the data support the potential clinical utility of F-rhPSMA-7.3.