Journal of clinical oncology : official journal of the American Society of Clinical Oncology 2013 Sep 16
Randomized controlled trial of intensity-modulated radiotherapy for early breast cancer: 5-year results confirm superior overall cosmesis.   
ABSTRACT
PURPOSE
There are few randomized controlled trial data to confirm that improved homogeneity with simple intensity-modulated radiotherapy (IMRT) decreases late breast tissue toxicity. The Cambridge Breast IMRT trial investigated this hypothesis, and the 5-year results are reported.
PATIENTS AND METHODS
Standard tangential plans of 1,145 trial patients were analyzed; 815 patients had inhomogeneous plans (≥ 2 cm(3) receiving 107% of prescribed dose: 40 Gy in 15 fractions over 3 weeks) and were randomly assigned to standard radiotherapy (RT) or replanned with simple IMRT; 330 patients with satisfactory dose homogeneity were treated with standard RT and underwent the same follow-up as the randomly assigned patients. Breast tissue toxicities were assessed at 5 years using validated methods: photographic assessment (overall cosmesis and breast shrinkage compared with baseline pre-RT photographs) and clinical assessment (telangiectasia, induration, edema, and pigmentation). Comparisons between different groups were analyzed using polychotomous logistic regression.
RESULTS
On univariate analysis, compared with standard RT, fewer patients in the simple IMRT group developed suboptimal overall cosmesis (odds ratio [OR], 0.68; 95% CI, 0.48 to 0.96; P = .027) and skin telangiectasia (OR, 0.58; 95% CI, 0.36 to 0.92; P = .021). No evidence of difference was seen for breast shrinkage, breast edema, tumor bed induration, or pigmentation. The benefit of IMRT was maintained on multivariate analysis for both overall cosmesis (P = .038) and skin telangiectasia (P = .031).
CONCLUSION
Improved dose homogeneity with simple IMRT translates into superior overall cosmesis and reduces the risk of skin telangiectasia. These results are practice changing and should encourage centers still using two-dimensional RT to implement simple breast IMRT.