Would you ever use a PET dotatate CT to monitor response of a GEP-NEN that is SSTR positive?
Or use baseline PET followed by serial MRI/CT for monitoring?
Answer from: Medical Oncologist at Academic Institution
I would use baseline PET/CT or PET/MR and then subsequent scans would be with cross-sectional imaging with CTs or MRIs (MRI EOVIST if the liver is involved). CTs and MRIs would give a much better assessment of sizes for the established lesions.
Comments
Medical Oncologist at Montefiore Einstein Comprehensive Cancer Center What if your disease is barely visible on CT/MRI b...
Medical Oncologist at Mayo Clinic In the era of 3+, Tesla MRIs that isn't something ...
What if your disease is barely visible on CT/MRI b...
In the era of 3+, Tesla MRIs that isn't something ...