Do you recommend the use of automated insulin delivery systems (such as Control IQ with Tandem insulin pumps) for managing gestational diabetes?
Currently, none of the current FDA-approved AID systems have algorithms set to achieve pregnancy-specific glucose goals. So using the manual mode with overnight target 90 along with appropriate bolus settings to keep PPG at goal is the most efficient.